How to work out the emissions from a gas bill
What you need from the bill
Natural gas is one of the simpler things to account for, because the figure you need is already printed on the bill and the factor for burning it is the same in every state. This article covers pipeline natural gas, the kind that arrives through a meter. Bottled LPG is a different fuel with its own factors.
The figure to look for is the usage for the billing period in megajoules (MJ). Use that and leave the dollar amount alone, because the dollars move with your tariff as well as with how much gas you burned.
Megajoules to gigajoules
The government's factors for gas are published per gigajoule (GJ), and a gigajoule is 1,000 megajoules, so the first step is to divide the bill's figure by 1,000. A site that used 500,000 MJ in a year used 500 GJ.
Scope 1: burning it
The National Greenhouse Accounts Factors give 51.53 kg of CO2-e for every gigajoule of natural gas burned on your premises, in the 2026 edition as in 2025. This is scope 1, because the gas is burned in your own boiler, oven or heater, and the figure doesn't change with where you are.
Scope 3: getting it to you
There's a second, smaller figure for producing the gas and piping it to your meter, which counts as scope 3 because it happens before the gas reaches you. This one does change by state:
| State or territory | Scope 3, kg CO2-e per GJ |
|---|---|
| NSW and ACT | 13.10 |
| Victoria | 4.00 |
| Queensland | 8.80 |
| South Australia | 10.70 |
| Western Australia | 4.10 |
| Tasmania | none published |
| Northern Territory | none published |
These are the figures for metro distribution. The workbook also publishes non-metro ones, and the difference is at most 7 per cent on the scope 3 part. No scope 3 figure is published for Tasmania or the Northern Territory, so gas there is reported as scope 1 only, and it's better to say that on the report than to borrow another state's number.
A worked example
Take the Victorian site that used 500,000 MJ, or 500 GJ. Scope 1 is 500 times 51.53, which is 25,765 kg, and scope 3 is 500 times 4.00, which is 2,000 kg, so the year's gas comes to 27.77 tonnes of CO2-e.
If the same site were in NSW, scope 1 would be identical and scope 3 would be 500 times 13.10, which is 6,550 kg, taking the total to 32.32 tonnes. The gas and the boiler are the same, and the difference comes entirely from the supply figure for the state.
What to watch for
A quarterly bill that runs across 30 June belongs partly to each reporting year, so decide how you'll treat those (by the bill's end date, or split by days), do it the same way every year and write down which you chose, because a reviewer comparing two years will want to know.
If you have sites in more than one state, work each one out separately, since the scope 3 figure is different for each. And because the government publishes a new edition of the factors every year, put the edition beside the number, so that anyone reading it later can see which table it came from.
Where CarbonCut fits
CarbonCut reads the bill for you and a person confirms every figure against the original before it goes into the baseline. It then applies the factor for your state and prints the factor, its source and its edition beside the result, and earlier years keep the factors they were reported under when a new edition comes out. Our gas factors were checked against the government's 2025 workbook on 19 August 2026, and the 2026 edition gives the same figures for every state.
The state table and the source are on the natural gas factor page, and if you only want a rough figure first, the quick estimate takes annual megajoules.